Respiratory Ventilator Medical PA 700B

R242,500.00 Ex VAT

Advanced Model Exclusive Features
Equipped with professional medical grade air compressor tailored for long clinical times and low noise requirements

 

This product is strictly by order only. Delivery is by air, from Dubai. Price does not include shipping Please allow 10 to 15 working days delivery. ( Delays is highly possible )

1 in stock

Description

Respiratory Ventilator Medical PA 700B

Ventilator with a medical air compressor(PA-700B)

  • The Ventilator is a universal multi-mode Ventilator, a multi-functional Ventilator, which can be used for clinical breath first aid and respiratory therapy.
  • With the control, auxiliary/control, intermittent instruction, manual and other breathing patterns, as well as breathing is not positive pressure, sigh and other respiratory function is the hospital’s essential breathing equipment.
  • Large-screen LCD display, 10.4 inch TFT color LCD screen. Dual flow sensor to ensure that the breath and inhale more secure, accurate.
  • Power-off-delay function.

ISO 13485 Certificate Ventilator with Medical Air Compressor (PA-700B)

ISO 13485 Certificate Ventilator with Medical Air Compressor (PA-700B)

Display  10.4” LCD Display
Mode: a pneumatically powered and electrically controlled system
Trolley: Fitted with 4 nos anti-static rubber castors; two of which

are lockable for braking and easy maneuverability with foot-operated brake provisions

Technical Specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa
safety valve <12.5  kPa
Respiratory Rate 1 ~ 99 bpm
Oxygen Concentration 21% ~ 100%
Maximum Minute ventilation ≥18L / min
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT
Ventilator compliance ≤30 Ml/kPa
PEEP: 0 ~ 1.0 kPa
Ptr: -10 ~ 10 hPa
IMV frequency: 1~20 bpm
I/E Ratio: 4:1~1:4, Has the inverse ratio ventilation
Tidal Volume Setting Range:  50~1500ML

Display Range: 0~2000ml ;  resolution ratio: 10ml

Inspiratory Plateau: 0~1s
Maximum Safety  Pressure ≤ 6.0kPa
Sigh: one deep breath per 80 controlled respirations,

the inspiration time is 1.5 times of the setting point

Pressure limit range: 1.0~ 6.0kPa
Airway pressure alarm: Audible and visual and

with yellow and red color indicating

Lower: 0.1 kPa ~ 6.0 kPa;   Upper: 0 ~ 5.0  kPa
±0.2 kPa
Ventilation Volume alarm: ≥ 18L/ MIN
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz;
Attention: the AC power supply used for the anesthesia

the machine must be well-grounded.

Storage
Ambient temperature: -15oC ~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
Between the packaging box and product, soft material

with appropriate thickness provided to prevent loosening

and mutual friction during transportation

Moisture protection and rain protection to ensure that

product is protected from natural damage.

Safety & Alarm
Gas source pressure Immediate alarm; “high level alarm” indicator flickers raising an audible alarm.
Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high-level alarm” indicator flickers raising an audible alarm. 
Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume Alarm Lower: 0~12L/Min;   Up: 18L/ Min
Battery Voltage Alarm It alarms when the battery voltage is lower than 10.5V.
Power On Self Test Self-test before working, assure it’s working normally.